MATERIAL
Forward AM (BASF) Ultracur3D ST 45 Black
Cleaning
Program C *
Ultracur3D cleaner for 3 mins.
Cleaning IPA Tank for 2 mins.
Rinsing IPA Tank for 1 min.
UV Curing
WRAP Prime: 30 mins.**
WRAPCure Certified: 30 mins.**
WRAPCure: 60 mins.**
Thermal Curing
Not Required
* The CleanPoint cleaning time specified above is standard for cleaning most parts. However, when parts contain complicated geometries such as blind holes, small grooves, or internal cavities, cleaning times may need to be extended. Please note, excess exposure to cleaning solvents may compromise mechanical properties. Certain geometries may require manual cleaning techniques.
** Parts must be dry before curing. After cleaning, dry parts with compressed air for 10 – 60 seconds. Allow parts to air dry for a minimum of 1 hour after cleaning to ensure complete solvent evaporation. For parts that underwent a 5-minute or more cleaning, extend the drying time to at least 3 hours.