MATERIAL
Henkel LOCTITE 3D 3955 Black
Henkel LOCTITE 3D 3955 Black has not yet been jointly validated by Onulis and Henkel. However, post-processing can be completed on Onulis systems using Custom Programming settings.
To confirm the steps below, please refer to the Henkel website.
Cleaning
Custom Program*
Rinsing Tank for 4 mins.
Cleaning Tank for 4 mins.
UV Curing
Not Required
Thermal Curing
Prog_5 or Custom Program **
Start Temperature: 25°C
Ramp 1: Ramp Up 3°C /min to 190°C
Hold: 6 hrs @ 190°C
Ramp 2: Ramp Up 3°C /min to 210°C
Hold: 1 hr @ 210°C
* The CleanPoint cleaning time specified above is standard for cleaning most parts. However, when parts contain complicated geometries such as blind holes, small grooves, or internal cavities, cleaning times may need to be extended. Please note, excess exposure to cleaning solvents may compromise mechanical properties. Certain geometries may require manual cleaning techniques.
** Parts must be dry before curing. After cleaning, dry parts with compressed air for 10 – 60 seconds. Allow parts to air dry for a minimum of 1 hour after cleaning to ensure complete solvent evaporation. For parts that underwent a 5-minute or more cleaning, extend the drying time to at least 3 hours.