MATERIAL
P3 Silicone 25A Grey
P3 Silicone 25A Grey has not yet been jointly validated by Onulis and Stratasys. However, post-processing can be completed on Onulis systems using Custom Programming settings and recommended cure times.
Cleaning
Program D *
Cleaning IPA Tank for 3 mins.
Rinsing IPA Tank for 3 mins.
Rinse part with acetone squeeze bottle and let dry.
UV Curing
WRAP Prime: 2.5 hrs.**
WRAPCure Certified: 2.5 hrs.**
WRAPCure: 5 hrs.**
Thermal Curing
Custom Program **
Ramp Up: 22°C to 85°C (3°C/min) for 30 mins.
Hold: 85°C for 18 – 24 hrs.
Ramp Down: Allow the oven to cool to room temperature with the oven door closed.
* The CleanPoint cleaning time specified above is standard for cleaning most parts. However, when parts contain complicated geometries such as blind holes, small grooves, or internal cavities, cleaning times may need to be extended. Please note, excess exposure to cleaning solvents may compromise mechanical properties. Certain geometries may require manual cleaning techniques.
** Parts must be dry before curing. After cleaning, dry parts with compressed air for 10 – 60 seconds. Allow parts to air dry for a minimum of 1 hour after cleaning to ensure complete solvent evaporation. For parts that underwent a 5-minute or more cleaning, extend the drying time to at least 3 hours.